Slider giải pháp

Our Solutions

Multi market supplier, we bring up development opportunities and offer comprehensive solutions which are suitable for the specific requirements of each customer.

Technical description
Instructions for use
Code Product Volume Dimensions Trocar diameter
RB002 Small Endo Pouch 255ml 100mm x 160mm 10mm/12mm
RB004 Medium/Large Endo Pouch 680ml 150mm x 180mm 10mm/12mm
RB006 Extra Large Endo Pouch  1500ml 190mm x 230mm 15mm
RB008 Extra Large Endo Pouch 1500ml 190mm x 230mm 12mm

How Supplied

Contents are sterile for single patient use only.

Do not use if the package is opened or damaged.

Do not re-sterilise.

Contraindications

This device is not intended for use when endoscopic techniques are contraindicated.

Cautions/Warnings

1. This device is designed for single use only, and is not to be reused or re-sterilised. Do not Use if package is opened or damaged.

2. Endoscopic procedures should be performed only by physicians with adequate training and knowledge of these procedures. In addition, medical literature should be consulted regarding techniques, hazards, contraindications, and complications prior to the performance of these procedures.

3. Before endoscopic instruments and accessories from different manufacturers are utilised together in a procedure, verify compatibility and ensure that electrical isolation of ground is not compromised.

4. A thorough understanding of techniques and principles involved in electrosurgical procedures is necessary to avoid burn or shock hazard to patient and or operator.

Indications for Use

To be used for removal of tissue specimens during a suitable Laparoscopic procedure.

Instructions for Use

1. Line up the arrow on the devices handle with the LaproSurge® logo adjacent to the finger slots further down the shaft.

2. Insert the retrieval system into an appropriately sized cannula.

3. Deploy the specimen bag by pushing the handle forward

4. Use an appropriate laparoscopic instrument to place the specimen into the retrieval bag.

5. Pull the internal obturator out from the black external sheath until the bag has detached.

6. Remove retrieval system from cannula.

7. Pouch is now sealed inside patient, and may be removed from abdomen.

8. If the retrieval bag with specimen cannot be removed, enlargement of the access site is recommended for easier removal

Detachable Endo Pouch

DESCRIPTION

  • Simple delivery device to aid rapid entry
  • Markings on handle show bag orientation
  • Bag is transparent for better visibility of specimen
  • Impermeable material minimizes port site contamination risks
  • Rigid wire holds mouth open wide for easy specimen capture
  • The bag is closed fully for specimen security using the strong nylon purse string
Liên hệ