Sản phẩm | Sản phẩm | Chiều dài | Số lượng |
5mm blunt tipped dissector (triple pack) | BD001 | 410mm | 20 x 3 |
5mm blunt tipped dissector (signle pack) | BD002 | 410mm | 30 x 1 |
5mm blunt tipped dissector (triple pack) | BD003 | 460mm | 20 x 3 |
Intended use
This instrument is intended to be used in laparoscopic and thoracoscopic surgery. Probe to carefully dissect tissue and reduce the risk of traumatic injury to adjacent anatomical structures.
Product description
The instrument has a small tip of fibrous material, which can protect anatomical structures from traumatic injury. It is intended for blotting tissues, assisting in defining and dissecting between surgical planes and for atraumatic retraction of organs.
Warning
• Verify the compatibility of instruments from different manufacturers prior to conducting the procedure.
• Endoscopic surgery should be performed only by physicians with adequate training and knowledge of these procedures.
• Do not use a damaged or faulty instrument. Check that the instrument is not bent, broken, cracked, or worn prior to use.
• The instrument should be used with an endoscope in laparoscopic and thoracoscopic procedures.
Caution
• Do not use excessive force or in a manner not consistent with normal instrumentation use.
Note
• The instrument is not intended for use when endoscopic techniques are contraindicated.
• Disposable devices are intended for single patient use only – DO NOT RESTERILISE.
• Dispose of all used or damaged products using standard hospital practiced for biohazard control.
• There is no contraindication that has direct connection with the instrument until now. Physicians should be aware whether patient can use this instrument according to the patient’s particular situation. Please check the latest medical document for detailed information.
General instructions for use
1. Inspect the instrument before use.
2. Insert the instrument through trocar.
3. Use it gently and keep the working end under full and unobstructed visualization during use.
Storage and Transportation
• Environment temperature range: -20°C ~ 50°C; relative humidity range : 10% ~ 80%;
• The instrument should be stored in controlled environment, protected from light, fire and vermin. Keep the environment clean, well ventilated and without corrosive gases.
The 5mm blunt dissector is a versatile instrument with multiple applications across various laparoscopic specialities. It is used to define surgical planes and expose structures during laparoscopic surgery. The small atraumatic tip allows the gentle dissection and manipulation of tissue while protecting delicate anatomical structures from the risk of traumatic injury.